Overview
Power Supply
220V~50Hz 50va
Temperature
0~30℃ (Rec. 15~25℃)
Specification
225mm*275mm*345mm
Product Description
The freezing point osmometer FPOSM-V2.0 is developed based on Raoul's freezing point theory. This principle states that a solution's freezing point decline is proportional to its molar concentration. By using high-sensitivity temperature sensing elements, the device accurately measures the freezing point of various solutions to derive osmotic pressure molar concentration. This technology is essential for pharmaceutical analysis, biological research, and food therapy.
Product Features
- Compliance & Security: Features electronic signatures and user classification management to satisfy CFR PART21 requirements, storing up to 3 years of testing data.
- High Precision: Supports single-point or multi-point (31-point) linear calibration to ensure detection accuracy across all range intervals.
- Automated Operation: Utilizes a screw linear guide motor design, allowing the entire test process to be completed via a simple touch screen interface.
- Double Refrigeration System: Short pre-cooling time and fast detection speed facilitate continuous sample processing.
- Multi-Display: Simultaneously displays osmotic pressure molar concentration, freezing point value, and molar concentration ratio.
- Low Maintenance: The cooling system uses an athermal transfer fluid design, reducing the need for frequent servicing.
- Pre-set Database: Built-in reference for hundreds of injectable drug names as per pharmacopoeia standards.
Product Parameters
| Measurement Range | 0 ~ 2000 mOsmol |
| Sample Amount | 100μl |
| Testing Duration | ≤ 3 min |
| Pre-cooling Time | ≤ 3 min |
| Measurement Error | ≤ 1% |
| Repeatability | ≤ 1% |
| Linearity | ≤ 1% |
| Resolution Ratio | 0.1 |
| Dimensions | 225mm * 275mm * 345mm |
Product Application
In the fields of biopharmaceutical development, clinical diagnostics, and drug quality control, accurate osmolality measurement is critical to ensuring drug safety and efficacy.
Company Profile
With a focus on gas detection and monitoring equipment, the organization has nearly 10 years of experience in retail, import, and export. The team provides tailored solutions for industrial, engineering, and shipping markets, ensuring high-quality standards and affordable service.
Currently serving customers in over 20 countries, including Brazil, Canada, Germany, Japan, Singapore, and the United States, the commitment remains to supply original merchandises and superior alternatives that meet diverse global requirements.
Frequently Asked Questions (FAQ)
Q: What is the measurement range of the FPOSM-V2.0?
A: The device measures osmotic pressure within the range of 0 to 2000 mOsmol.
Q: How much sample is required for a single test?
A: Only a small sample amount of 100μl is needed for accurate measurement.
Q: Does the instrument comply with regulatory data standards?
A: Yes, it satisfies CFR PART21 requirements with electronic signatures and 3-year data storage capabilities.
Q: How long does a single test take?
A: The testing duration is typically less than or equal to 3 minutes, following a pre-cooling time of same duration.
Q: Is the system difficult to maintain?
A: No, the cooling system uses an athermal transfer fluid design which exempts the user from frequent maintenance.